How do I check total water salinity?
Date: 2019-08-20
Click: 95
Author: Hymatic
In practice, a 25 Kg bag of table salt for every 50 m3 volume of water will be sufficient. Once the salinity is set correctly, there is no need to repeat.

In order for the system to function correctly, total salinity of the water must be greater than 500- 600 mg/l. In order to verify this, it is necessary to set the power shown at the control unit:

- Electrode voltage: must be less than 9.5 V
- Electrode amps: must be between 5.5 - 6 A.

In the event that these parameters fail to raise the salinity of the water by 100 mg/l, you need to pour 1.5 kg table salt for every 10 m3 of pool and allow it to dissolve. In practice, a 25 Kg bag of table salt for every 50 m3 volume of water will be sufficient. If it fails to rise, continue pouring until the correct strength is reached. Once the salinity is set correctly, there is no need to repeat.